Technical specifications for Booksize format

 

General technical specifications

Unless explicitly specified otherwise, the following technical specifications are valid for all components of the SINAMICS S120 booksize drive system.
 

Note:

When engineering the complete SINAMICS S120 drive, the system data of the associated Control Units, supplementary system components, DC link components and Sensor Modules must be taken into consideration.

Electrical specifications

Line voltage

380 ... 480 V 3 AC ±10 % (-15 % <1 min)

Line system configurations

Grounded TN/TT systems and non-grounded IT systems

Line frequency

47 ... 63 Hz

Electronics power supply

24 V DC -15 %/+20 %1), safety extra low-voltage (PELV/SELV)

Short-circuit current rating (SCCR)

(Short Circuit Current Rating)
according to UL 508C (up to 600 V)

1.1 ... 447 kW: 65 kA

Electromagnetic compatibility

According to EN 61800‑3

Second environment, Category C2/C3

For further information, see section Configuration notes

Overvoltage category

According to IEC/EN 61800‑5‑1

III

Mechanical specifications

Degree of protection

 

  • According to EN 60529

IP20

  • According to UL 508C/UL 61800‑5‑1

Open type

Protection class

 

  • Line circuits with protective conductor connection according to IEC 61800‑5‑1

I

  • Electronic circuits

Safety extra low-voltage PELV/SELV

Ambient conditions

 

Storage

Transport

Operation

In product packaging

In transport packaging

 

Climatic environmental conditions

Class 1K4
acc. to EN 60721‑3‑1
-25 ... +55 °C (-13 ... +131 °F)

Class 2K4
acc. to EN 60721‑3‑2
-40 ... +70 °C (-40 ...+158 °F)

Class 3K3 3)
acc. to EN 60721‑3‑3
For operation without derating4): 0 ... +40 °C (32 ...104 °F)
For operation with derating: >40 ... +55 °C (>104 ... 131 °F)

Relative humidity 5 ... 95 %

Environmental class/harmful chemical substances

Class 1C2
acc. to EN 60721‑3‑1

Class 2C2
acc. to EN 60721‑3‑2

Class 3C2
acc. to EN 60721‑3‑3

Organic/biological influences

Class 1B1
acc. to EN 60721‑3‑1

Class 2B1
acc. to EN 60721‑3‑2

Class 3B1
acc. to EN 60721‑3‑3

Pollution degree 2)

acc. to IEC/EN 61800‑5‑1

2

Installation altitude

 

  • Up to 1000 m (3281 ft) above sea level

Without derating

  • From 1000 m (3281 ft) up to 2000 m (6562 ft) )above sea level observe the derating characteristics
  • Reduction of the output current by 10 % per 1000 m (3281 ft) or
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)
  • From 2000 m (6562 ft) up to 4000 m (13123 ft) above sea level observe the derating characteristics

 

  • Power components
  • Reduction of the output current by 10 % per 1000 m (3281 ft) or
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)

and additionally:

  • Operation on line supply systems with grounded neutral point, or
  • Operation with an isolating transformer with secondary grounded neutral point
  • Control Units
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)

Mechanical strength

 

Storage

Transport

Operation

In product packaging

In transport packaging

 

Vibratory load

Class 1M2
acc. to EN 60721‑3‑1

Class 2M3
acc. to EN 60721‑3‑2

Class 3M1
acc. to EN 60721‑3‑3
Test valuesacc. to EN 60068‑2‑6 :
10 oscillations per axis in the range: 10 ... 57 Hz constant deflection 0.075 mm
57 ... 150 Hz constant acceleration 9.81 m/s2(1 × g)

Shock load

Class 1M2
acc. to EN 60721‑3‑1

Class 2M3
acc. to EN 60721‑3‑2

Class 3M1
acc. to EN 60721‑3‑3
Test valuesacc. to EN 60068‑2‑27 :
3 shocks per axis in both directions
Peak acceleration 49 m/s2 (5 × g); duration 30 ms

Certificates

Declarations of conformity

CE (Low Voltage, EMC and M​achinery Directive)

Certificates of suitability

cULus

 

1) When using a motor holding brake, restricted voltage tolerances (24 V ±10 %) might need to be taken into account.
 

2) The components must be protected against conductive pollution, e.g. by installing them in a control cabinet with degree of protection IP54 according to IEC 60529 or NEMA 12. If conductive pollution can be excluded at the installation site, a lower degree of cabinet protection is permissible.
 

3) Better than 3K3 through increased ruggedness regarding the temperature range and humidity. Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing water and water jets are not permitted.

4) Also carefully observe the permissible temperatures for the Control Unit and operator panel.

 

Chi tiết về sản phẩm SINAMICS S120 built-in units > Booksize format > Basic Line Modules in booksize format

 

Basic Line Modules are used for applications in which no energy is returned to the supply or where the energy exchange between motor and generator axes takes place in the DC link. Basic Line Modules can only feed energy from the supply system into the DC link, energy cannot be fed back into the supply system. The DC link voltage is directly derived from the 3-phase line voltage via a 6-pulse bridge circuit. Basic Line Modules are suitable for connection to grounded, star TN, TT and non-grounded symmetrical IT supply systems. The connected Motor Modules are pre-charged over the integrated pre-charging resistors (20 kW and 40 kW) or through activation of the thyristors (100 kW).
 

The 20 kW and 40 kW Basic Line Modules are equipped with an integrated brake chopper and can be directly used for applications in generating mode after connecting an external braking resistor.

A Braking Module is only required with a 100 kW Basic Line Module in generating mode.

 

Design

The Basic Line Modules in booksize format feature the following connections and interfaces as standard:

- 1 power connection
- 1 connection for the 24 V DC electronics power supply
- 1 DC link connection
- 3 DRIVE‑CLiQ sockets
- 1 connection for braking resistor
(20 kW (25 hp) and 40 kW (50 hp) Basic Line Modules only)
- 1 temperature sensor input for KTY84‑130, Pt1000 or PTC (Pt1000 can be used from firmware V4.7 HF17)


The status of the Basic Line Modules is indicated via two multi-color LEDs.


The scope of supply of the Basic Line Modules includes:

- DRIVE-CLiQ cable for connection to the adjacent Control Unit on the left for drive control, length 0.11 m (4.33 in)
- DRIVE‑CLiQ cable (length depends on Basic Line Module width) for connection to the adjacent Motor Module, length = width of Basic Line Module + 0.11 m (4.33 in)
- Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
- 24 V terminal adapter (X24)
- Connector X21
- 2 blanking plugs for sealing unused DRIVE‑CLiQ sockets
- 1 set of warning labels in 30 languages


Integration

The Basic Line Module receives its control information via DRIVE-CLiQ from:

  • CU320‑2 Control Unit
  • SINUMERIK 840D sl with
  + NCU 710.3B PN
  + NCU 720.3B PN
  + NCU 730.3B PN
  + Numeric Control Extensions NX10.3/NX15.3

- SIMOTION D

Connection example of 20 kW and 40 kW Basic Line Modules in booksize format


Note:

The thermostatic switch built into the braking resistor must be looped into the shutdown chain of the drive to prevent thermal overloading of the system in the event of a fault. If a braking resistor is not connected, a jumper must be connected between X21.1 and X21.2.

Connection example of 100 kW Basic Line Module in booksize format

 

Technical specifications

 

Basic Line Module in booksize format

6SL313...

Line voltage

(up to 2000 m (6562 ft) above sea level)

380 ... 480 V 3 AC ±10 % (-15 % <1 min)

Line frequency

47 ... 63 Hz

SCCR (short-circuit current rating)

65 kA in conjunction with the recommended Class J fuse, or circuit breaker according to UL489 / CSA 22.2 No. 5-02

see recommended line-side components

Line power factor

at rated power

 

  • Fundamental (cos φ1)

>0.96

  • Total (λ)

0.75 ... 0.93

Overvoltage category

according to EN 60664‑1

Class III

DC link voltage, approx.

1.35 × line voltage 1)

Electronics power supply

24 V DC -15 %/+20 %

Radio interference suppression

 

  • Standard

 

  • 20 kW and 40 kW (25 hp and 40 hp) Basic Line Modules

No radio interference suppression

  • 100 kW (125 hp) Basic Line Module

Category C3 to EN 61800‑3
Total cable length up to 350 m (1148 ft) (shielded)

  • With line filter

Category C2 to EN 61800‑3
Total cable length up to 350 m (1148 ft) (shielded)

Type of cooling

Internal air cooling (power units with increased air cooling by built-in fan)

Permissible ambient and coolant temperature (air)

during operation for line-side components, Line Modules and Motor Modules

0 ... 40 °C (32 ... 104 °F) without derating,
> 40 ... 55 °C (104 ... 131 °F), see derating characteristics

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft) above sea level, see derating characteristics

Declarations of conformity

CE (Low Voltage and EMC Directives)

Certificate of suitability

cULus

 

1) The DC link voltage is unregulated and load-dependent. For further information see section Configuration notes.

Line voltage 380 ... 480 V 3 AC

Basic Line Modules in booksize format

Internal air cooling

 

6SL3130-1TE22-0AA0

6SL3130-1TE24-0AA0

6SL3130-1TE31-0AA0

Power

 

 

 

 

  • Rated power Prated
       
  • At 380 V 3 AC

kW

20

40

100

  • At 460 V 3 AC 2)

(hp)

(25)

(50)

(125)

  • For S6 duty (40 %) PS6

kW

26

52

130

  • Pmax

kW

60

120

175

Braking power

with external braking resistor

 

 

 

 

  • PBmax. (=2 × Prated)

kW

40

80

  • Continuous braking power Pd(=0.25 × Prated)

kW

5

10

DC link current

 

 

 

 

  • At 600 V DC

A

33.5

67

167

  • For S6 duty (40 %)

A

43

87

217

  • Maximum

A

100

200

292

Input current

 

 

 

 

  • Rated current
    at 380 V 3 AC

A

35

70

172

  • Maximum

A

100

188

290

Activation threshold

Braking module

V

774

774

Resistance value

of the external braking resistor

Ω 

≥14.8

≥7.4

Cable length, max.

to braking resistor

m (ft)

15 (50)

15 (50)

Connection for braking resistor (X2)

 

Screw-type terminals

Screw-type terminals

  • Conductor cross-section, max.

mm2

0.5 ... 4

0.5 ... 10

Current requirement, max.

24 V DC electronic power supply

A

1

1.4

2

Current carrying capacity

 

 

 

 

  • 24 V DC busbars

A

20

20

20

  • DC link busbars

A

100

200

200

DC link capacitance

 

 

 

 

  • Basic Line Module

μF

940

1880

4100

  • Drive line-up, max.

μF

20000

20000

50000

Power loss 1)

kW

0.144

0.284

0.628

Cooling air requirement

m3/s (ft3/s)

0.016 (0.6)

0.031 (1.1)

0.05 (1.8)

Sound pressure level

LpA (1 m/3.28 ft)

dB

<60

<65

<65

Line connection

U1, V1, W1

 

Screw-type terminals

Screw-type terminals

M8 screw stud

  • Conductor cross-section, max.

mm2

0.5 … 16

10 ... 50

1 × 35 ... 120 or
2 × 50

Shield connection

 

Integrated into the power plug

See Accessories

See Accessories

PE connection

 

M5 screw

M6 screw

M6 screw

Cable length, max.

(total of all motor power cables and DC link)

 

 

 

 

  • Shielded/unshielded

m (ft)

1000/1500 (3281/4922)

1000/1500 (3281/4922)

1000/1500 (3281/4922)

Degree of protection

 

IP20

IP20

IP20

Dimensions

 

 

 

 

  • Width

mm (in)

100 (3.94)

150 (5.91)

200 (7.87)

  • Height

mm (in)

380 (14.96)

380 (14.96)

380 (14.96)

  • Depth

mm (in)

270 (10.63)

270 (10.63)

270 (10.63)

Weight, approx.

kg (lb)

6.8 (14.9)

11.3 (24.9)

15.8 (34.8)

 

1) Power loss of Basic Line Module at rated output including losses of 24 V DC electronics power supply.

2) Nominal hp ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be dimensioned accordingly.

 

Characteristic curves

 

Overload capability

Duty cycle with previous load

Duty cycle with previous load

S6 duty cycle with previous load

20 kW (25 hp) and 40 kW (50 hp) Basic Line Modules only

Duty cycle with previous load
 

Derating characteristics

Output power as a funcction of ambient temperature


Installation altitude

- >1000 ... 4000 m (3281 ... 13124 ft) above sea level
  + Reduction of the output current by 10 % per 1000 m (3281 ft), or
  + Reduction of the ambient temperature by 5 °C (9 °F) per 1000 m (3281 ft)

- >2000 ... 4000 m (6562 ... 13124 ft) above sea level
  + Operation on line supply systems with grounded neutral point, or
  + Operation with an isolating transformer with secondary grounded neutral point
 

Braking power with external braking resistor

The following duty cycles are defined for the braking modules of the 20 kW and 40 kW Basic Line Modules:

The maximum possible braking power Pmax is calculated using the following formula:

Pmax = U2/R

U = Activation threshold

R = Resistance value of the external braking resistor


The maximum braking power is achieved with the smallest permissible resistance value. The maximum possible braking power falls at larger resistance values.

Braking power of the 20 kW Basic Line Modules depending on the connected braking resistor

When the recommended braking resistor is used, the following values result for the maximum braking power or continuous braking power:

Braking resistor 6SE7023-2ES87-2DC0
Resistance value = 20 Ω → max. braking power = 30 kW; continuous braking power = 5 kW

Braking power of the 40 kW Basic Line Modules depending on the connected braking resistor

When the recommended braking resistor is used, the following values result for the maximum braking power or continuous braking power:

Braking resistor 6SE7028-0ES87-2DC0
Resistance value = 8 Ω → max. braking power = 75 kW; continuous braking power = 10 kW (limited by braking module)

 